ACB REPAIRING SERVICES

Air Circuit Breaker (ACB) Maintenance

We advise a suitable maintenance schedule to guarantee your equipment operates dependably. We visit sites for routine maintenance as well as in case of emergencies when an ACB is not operating properly.

Each site and ACB are unique. This indicates that a service schedule will be evaluated following a meeting or visit with you. The schedule is based on the environment the ACBs operate in and how frequently they operate; insufficient use necessitates maintenance just as much as excessive use does.

With the help of our service plan, we can repair or remove your breakers as needed and work on them on-site. Some components of the ACB are disassembled during the service to allow for inspection, lubrication, repair, and testing. We can test the functionality of the ACBs electronic trip units and their parameters thanks to a variety of specialised secondary injection test equipment.

Distribution & Control Panel Maintenance

Additionally, we provide a free service for your distribution and control panels. We advise cleaning the panels’ interior and exterior on a regular basis to get rid of dust and dirt. The supply and distribution busbar connections can be re-torqued at the same time as the switchgear connections can be checked and tightened. We have observed numerous instances where system failure due to lack of maintenance can result in noise, excessive heat, and loose connections on busbars.

VCB REPAIRING SERVICES

Cleaning, tightening, and disassembling of every auxiliary and control unit connection point. Hand pullout system assembly, chassis cleaning, grease application, and function position indicators assembly. Arc chute disassembly, cleaning, inspection, and assembly. testing the control unit physically. assembly, cleaning, inspection, and testing of the tripping and closing coils. electrical spring charging motor disassembling, cleaning, and reassembling. The mechanical charging system needs to be cleaned and greased. cluster assembly, cleaning, lubrication, and disassembly. checking the ON/OFF switch. Vacuum interrupter inspection Cleaning movable mechanical parts and testing lubricants. Relay testing using secondary injections. Through an earth fault relay and an overcurrent device, the VCB is tested. Auxiliary relay testing.OTI, WTI, and the Buckhloz relay cause the VCB to trip. primary injection-based VCB tripping. assembly of the locking mechanism, push button, and front cover after being disassembled, cleaned, and assembled. Arc chute cover and terminal shield disassembly and cleaning. CE switches must be disassembled, cleaned, and reassembled. auxiliary and control unit connection block disassembly, cleaning, and tightening at every point. Hand pullout system, mechanism chassis, and function position indicators are disassembled, cleaned, greased, and reassembled. cleaning, inspecting, disassembling, and reassembling the arc chute. Control unit physical testing. Tripping coil/closing coil disassembly, cleaning, inspection/testing, and assembly. The electrical spring charging motor is disassembled, cleaned, and put back together. Mechanical charging system cleaning and lubrication cleaning, lubricating, disassembling, and reassembling clusters.

PANEL REPAIRING SERVICES

Control Panel Repairing Service from Sadguru Electricals is well-known in the industry for its high calibre and dependability. Our skilled employees make sure that their work leaves our valued customers pleased. We offer repairs for burned-out components, any faults or damage, and rewiring for outdated panels. Additionally, the aforementioned Control Panel Repairing Service helps to increase power factor, convert manual mode to automatic mode, and other things. With utm, we are able to provide this service at a very reasonable cost. Our business provides Control Panel Repair Service and has a wealth of experience in this field. Experts perform this service quickly and efficiently. This service is accomplished in timely manner by experts. These facilities are offered by us at market leading prices ensuring quality and customers satisfaction cost care and dedication. Experts perform this service quickly and efficiently. We provide these services at prices that are competitive in the market, ensuring both quality and customer satisfaction.

ACB & VCB PANEL ANNUAL CONTRACT

Additionally, we provide a free service for your distribution and control panels. We advise cleaning the panels’ interior and exterior on a regular basis to get rid of dust and dirt. The supply and distribution busbar connections can be re-torqued at the same time as the switchgear connections can be checked and tightened. We have observed numerous instances where system failure due to lack of maintenance can result in noise, excessive heat, and loose connections on busbars.

Common mistakes we observe:

(Turn “OFF”) Air Circuit Breaker won’t open
(Turn “ON”) Air Circuit Breaker won’t close
Inability to recharge or reset an air circuit breaker
Air Circuit Breaker will not trip as intended or necessary.
When turned on, the air circuit breaker will not stay closed.

Tripping off of the air circuit breaker in a random or bothersome manner

The majority of these common faults can be prevented with the right maintenance schedule.

PANEL ANNUAL CONTRACT

Three times per year, or as needed on the job site, air circuit breakers (ACBs) or voltage control breakers (VCB) must be serviced or overhauled, which includes the following tasks:
Assembly of front cover, push button, locking latches, etc. after disassembly, cleaning, etc. Arc chute covers, covers, and terminal shields are taken apart, cleaned, and put back together. cleaning, disassembling, and reassembling of chassis cleaning, tightening, and disassembling of every auxiliary and control unit connection point. Cleaning, lubricating, and reassembling the hand pullout system, the chassis’ racking mechanism, and the function position indicators Arc chute disassembly, cleaning, inspection, and assembly. Physical examination of the primary contact. Physical examination and pull rod and contact gap adjustment. Examination, maintenance, and setting of trip releases. Cleaning, inspecting, testing, and reassembling the tripping and closing coils. electrical spring charging motor disassembling, cleaning, and reassembling. Mechanical charging system disassembly, cleaning, greasing, and assembly. jaw contacts disassembling, cleaning, lubricating, and reassembling. Testing the springtime, trip time, and closing time in accordance with standards. measurement and inspection of the contact resistance, trip coil resistance, and closing coil resistance. lubricating the knife, linkage, and inner mechanism roller. using petroleum jelly on the contact between clusters. All ACB/VCB components should be cleaned using gasoline and CRC in accordance with industry standards. final examination of the circuit breaker’s electrical and mechanical capabilities.

Natural Natural Natural Natural Natural Natural Natural Natural Natural Natural Natural

Happy Customers

Projects Completed

Hours of Support

Skilled Workers

TESTIMONIALS

Customer Satisfaction

Everything was very satisfactory. THANK YOU For your efficient service. Will be happy to recommend you. I am really happy I chose SADGURU ELECTRICALS.

- ISHAN SINNARKAR

ON-TIME DELIVERY

They promised to deliver the product at a specific time and guess what, they delivered even before the deadline. Very humble staff.

- Varad Vaidya

EXCELLENT SERVICE

From the first moment that we walked into the office at Sadguru Electricals, the staff was AMAZING! We were introduced to an experienced team who solved our problem within given time frame.

- CHANDAN SUTHAR

Got an Electrical Project or Problem?

× How can I help you?